22 Jul

Fluke 730G Digital Pressure Calibrator

WhatsApp for Price

Key features

  • Pressure measurement from ±10 inH2O/2.5 kPa to 10000 psi/69 MPa
  • Four absolute pressure measurement ranges: 15 PSIA (103 kPa), 30 PSIA (207 kPa), 100 PSIA (690 kPa), 300 PSIA (2 MPa)
  • Pressure measurement accuracy 0.05% of full scale, 0.02% optional
  • Current measurement range: 0-24mA
  • Voltage measurement range: 0-30VDC
  • 0.01% current and voltage accuracy
  • Powerful HART communication, supports HART 7
  • 24V loop power, no external power supply needed
  • Lithium battery life: 25 hours continuously (without 24 V loop power), or 8 hours continuously (24 V loop power)
  • Storage up to 128 sets of calibration data
  • Ingress protection: IP54
  • 1-meter drop test 
  • Three-year warranty

Description

Product overview: Fluke 730G Digital Pressure Calibrator

A compact, smart pressure solution for bench or field
The Fluke 730G Smart Digital Pressure Calibrator combines the performance of a precision test gauge with the power of a loop calibrator and also includes internal HART communication capabilities. When used with a pressure test pump the Fluke 730G becomes a high-efficiency, highly accurate calibrator that can test pressure gauges, pressure switches and pressure transmitters making it ideal for instrument shops, gauge labs and pressure laboratories.

  • Built-in HART Communication: The integrated HART communication functionality is easy-to-use and allows you to adjust HART directly, without requiring additional tools for adjustment.
  • Precision Pressure and Current Measurements: The 730G series provides high-precision 0.02% pressure measurement accuracy and 0.01% current measurement accuracy to meet the requirements for establishing a pressure laboratory and achieving accurate pressure calibration results.
  • Intuitive operation and ease of use: A high-end LCD display and dual-jack design bring a more convenient and efficient user experience.
  • Paperless testing and reporting: Optional 730G/PCSW management software enables paperless testing giving you the ability to automatically generate test reports and document results.

Fluke 730G/PCSW Software

  • Paperless management of pressure calibrations:  Record calibration data, automate calibration tests and generate calibration reports.
  • Asset management: Manage tested equipment and pressure standards with ease.
  • Supported pressure devices include: analog pressure gauges, digital pressure gauge, pressure transmitter, pressure sensors and pressure switches.

Increase your pressure testing capabilities using test pump kits
Fluke-700PTPK Pneumatic test pump kit:

  • Combine with any Fluke-730G Series Gauge, 1000 psi (69 bar) or less
  • Generate pressure up to 600 psi (40 bar) with the 700PTP-1 test pump
  • Connect the 730G Series gauge directly to the included PTP-1 hand pump
  • Includes hoses and adapters for connecting to the pressure device to be tested
  • Hard case protects pump and gauge and allows gauge to remain connected to the pump

Fluke-700HTPK Hydraulic Test Pump Kits

  • Combine with any Fluke-730G Series Gauge, 1000 psi (69 bar) or greater
  • Generate pressure up to 10000 psi (690 bar) with the 700HTP-2 test pump
  • Connect the 730G Series gauge directly to the HTP-2 hand pump
  • Includes 700HTH-1 hoses and adapters for connecting to the pressure device to be tested.
  • Hard case protects pump and gauge and allows gauge to remain connected to the pump

Specification

Specifications: Fluke 730G Digital Pressure Calibrator

Technical specifications
Pressure specifications: 0.02% of full scale (730RG), 0.05% of full scale (730G)
Current specifications: 0.01% of reading
Model Range Resolution Accuracy1 Burst pressure
730G01 -10 to +10 inH2O-20 to 20 mbar-2.49 to 2.49 kPa 0.001 inH2O0.001 mbar0.0001 kPa Positive pressure, ±0.2% of range2
Vacuum, ±0.2% of range2
3 psi,210 mbar20.6 kPa
730G02 -1 to +1 psi-70 to 70 mbar-6.89 to 6.89 kPa 0.0001 psi0.001 mbar0.0001 kPa 5 psi,350 mbar34.4 kPa
730G04 -14 to 15 psi-0.97 to 1 bar-97 to 103 kPa 0.001 psi0.0001 bar0.01 kPa Positive pressure, ±0.05% of rangeVacuum, ±0.1% of range 60 psi4 bar413.6 kPa
730G05 -14 to 30 psi-0.97 to 2 bar-97 to 206 kPa 0.001 psi0.0001 bar0.01 kPa 120 psi8 bar827.3 kPa
730G06 -12 to 100 psi-0.83 to 6.9 bar-83 to 690 kPa 0.01 psi, 0.0001 bar 400 psi26 bar2.757 MPa
730G27 -12 to 300 psi-0.83 to 20 bar-83 to 2 MPa 0.01 psi0.001 bar0.1 kPa 1200 psi80 bar8.273 MPa
730G07 -12 to 500 psi-0.83 to 34 bar-83 to 3.4 MPa 0.01 psi0.001 bar0.1 kPa 2000 psi138 bar13.789 MPa
730G08 -14 to 1000 psi,-0.97 to 69 bar-97 to 6900 kPa 0.01 psi0.001 bar0.1 kPa 4000 psi266 bar27.579 MPa
730G10 -14 to 2000 psi,-0.97 to 140 bar-97 to 14 MPa 0.1 psi0.01 bar1 kPa 8000 psi550 bar55.158 MPa
730G29 -14 to 3000 psi,-0.97 to 200 bar-97 to 20 MPa 0.1 psi0.01 bar1 kPa 10000 psi690 bar68.947 MPa
730G30 -14 to 5000 psi,-0.97 to 340 bar-97 to 34 MPa 0.1 psi0.01 bar1 kPa 10000 psi690 bar68.947 MPa
730G31 -14 to 10000 psi,-0.97 to 690 bar-97 to 69 MPa 1 psi0.01 bar1 kPa 15000 psi1035 bar103.421 MPa
730GA4 0 to 15 psia,0 to 1 bar0 to 100 kPa absolute pressure 0.001 psi0.0001 bar0.01 kPa ±0.05% of range4 60 psi4 bar413.6 kPa
730GA5 0 to 30 psia0 to 2 bar0 to 200 kPa absolute pressure 0.001 psi0.0001 bar0.01 kPa 120 psi8 bar827.3 kPa
730GA6 0 to 100 psia,0 to 6.9 bar0 to 690 kPa absolute pressure 0.01 psi0.0001 bar0.01 kPa 400 psi27 bar2.757 MPa
730GA27 0 to 300 psia0 to 20 bar0 to 2 MPa absolute 0.01 psi0.001 bar.01 kPa 1200 psi80 bar8.273 MPa
730RG04 -14 to 15 psi,-0.97 to 1 bar-97 to 100 kPa 0.001 psi 0.0001 bar0.0001 kPa Positive pressure, ±0.02 % of range3Vacuum, ±0.05 % of range3 45 psi3 bar310.2 kPa
730RG05 -14 to 30 psi,-0.97 to 2 bar-97 to 200 kPa 0.001 psi 0.0001 bar0.01 kPa 90 psi6 bar620.5 kPa
730RG06 -12 to 100 psi,-0.83 to 6.9 bar-83 to 690 kPa 0.01 psi 0.0001 bar0.01 kPa 1000 psi69 bar6.894 MPa
730RG27 –12 psi to 300 psi-0.83 to 20 bar–80 kPa to 2 MPa 0.01 psi0.001 bar0.1 kPa 2000 psi138 bar14 MPa
730RG07 –12 psi to 500 psi-0.83 to 34 bar–80 kPa to 3.5 MPa 0.01 psi0.001 bar0.1 kPa 2000 psi138 bar13.789 MPa
730RG08 -14 to 1000 psi,-0.97 to 69 bar-97 to 6900 kPa 0.1 psi0.001 bar0.1 kPa 10000 psi690 bar68.947 MPa
730RG29 -14 to 3000 psi-0.97 to 200 bar-97 to 20 MPa 0.1 psi0.01 bar1 kPa 10000 psi690 bar68.947 MPa
730RG30 -14 to 5000 psi,-0.97 to 340 bar-97 to 34 MPa 0.1 psi0.01 bar1 kPa 10000 psi690 bar68.947 MPa
730RG31 -14 to 10000 psi,-0.97 to 690 bar-97 to 69 MPa 0.1 psi0.01 bar1 kPa 15000 psi1035 bar103.421 MPa
Accuracy specifications above have considered the effects of linearity, repeatability, resolution, reference accuracy, 1-year stability, and temperature effect.2 For 730G01/730G02, accuracy is ±0.3% of full scale @ 0 °C to 15 °C and 35 °C to 50 °C.3 For all 730RG model, add 0.003% FS/°C @ 0 °C to 18 °C and 28 °C to 50 °C。4 For 730GA4, add 0.006% FS/°C @ -10 °C to 15 °C and 35 °C to 55 °C; for all other 730GA model, add 0.003% FS/°C @ -10 °C to 15 °C and 35 °C to 55 °C.
Media Compatibility730G01, 730G02, 730G04, 730G05, 730RG04, 730RG05: any clean dry non-corrosive gasAbove 100 psi: any liquids or gases compatible with 316 stainless steel
Electrical specifications (All specifications are valid to 110% of range)
Current 0 mA to 24 mA
Voltage 0 V DC to 30 V DC
Current range 1 μA
Voltage range 1 mV
Accuracy 0.01% ± 2 LSD all ranges @ 23°C ±5 °C
Temperature compensation From 20% FS/°C @ -10 °C to +18 °C and 28 °C to 50 °C
Loop Compliance Voltage 24 V DC @ 20 mA
Temperature measurement accuracy inside the product ±0.5 ℃
Drive Capability 1200 Ω (without HART resistor), 950 Ω (with internal HART resistor)

Datasheet