27 Jan

Hioki Power Meter Analyzer PW8001

WhatsApp for Price

 

DC, 0.1 Hz to 5 MHz, 3-phase 4-wire, High Precision Power Analyzer for Motor and Inverter Efficiency Analysis

Category: Brand:

Description

The PW8001 sets a new benchmark for complete power analysis solutions with Hioki being the only manufacturer that offers industry-leading power analyzers and a wide portfolio of high-accuracy current sensors both developed and manufactured by Hioki. This enables to align their performance and results in more accurate and stable measurements from DC to high frequencies and low power factor measurements thanks to functions like the automatic phase shift correction.Upcoming industry challenges are anticipated with the ability to measure even large currents at voltages up to 1500 V, 15 MS/s sampling rate and multi-channel measurement target applications using SiC/GaN semiconductors from automobile electrification, smart grids and reactors to renewable energy supply sources.

Key Features

  • World-class measurement accuracy: Basic accuracy ±0.03%, DC accuracy ±0.05%, 50 kHz accuracy 0.2% (*1)
  • Accurate capture of power fluctuations caused by high-speed switching: Sampling performance 18-bit, 15 MHz, Noise Resistance (CMRR) 110 dB, 100 kHz (*1)
  • Up to 8 power channels optimizing your measurement: 8-channel power measurement
  • Accurately measure high-frequency, low-power-factor power: Current sensor automatic phase correction function (*2)
  • Simultaneous analysis of 4 motors: 4-motor/2-motor simultaneous analysis function
  • Integration of measurement data into CAN networks: CAN or CAN FD output function
  • Intuitive and Quantitative Insights with Power Spectrum Analysis (PSA) function
  • Safe evaluation of increasingly high-voltage solar inverters: 1500 V DC CAT II / 1000 V DC CAT III (*3)
  • Earning Japan Calibration Service System (JCSS) Certification for DC Power Measurement. (*4)

*1:When using the 15MS/S Input Unit U7005

*2:When used with a current sensor with automatic phase correction functionality

*3:When using the 2.5MS/S Input Unit U7001

*4:JCSS is standard that is satisfy the requirements of the ISO/IEC 17025 international standard.

Learn more

 

Model No. (Order Code)

PW8001-01
PW8001-02 D/A output
PW8001-03 CAN or CAN FD output
PW8001-04 Optical link interface
PW8001-05 D/A output, optical link interface
PW8001-06 CAN or CAN FD output, optical link interface
PW8001-11 Motor analysis
PW8001-12 Motor analysis, D/A output
PW8001-13 Motor analysis, CAN or CAN FD output
PW8001-14 Motor analysis, optical link interface
PW8001-15 Motor analysis, D/A output, optical link interface
PW8001-16 Motor analysis, CAN or CAN FD output, optical link interface
Note: Input units must be specified at the time of ordering. Optional input units, voltage cords, and current sensors are required for measurement.

Specification

Basic specifications
Accuracy guaranteed for 6 months, multiply the 6-month accuracy reading error by 1.5 to obtain the 1-year accuracy.
Measurement lines 1-phase-2-wire, 1-phase-3-wire, 3-phase-3-wire, 3-phase-4-wire
No. of PW8001 input units Max. 8 units (mix and match)
Type of input unit U7001 2.5 MS/s INPUT UNIT
U7005 15 MS/s INPUT UNIT
Measurement frequency band U7001: DC, 0.1 Hz to 1 MHz
U7005: DC, 0.1 Hz to 5 MHz
Sampling U7001: 2.5 MHz, 16-bit
U7005: 15 MHz, 18-bit
Data update rate 1 ms, 10 ms, 50 ms, 200 ms
Accuracy for power (U7001) 50/60 Hz: 0.02% of reading + 0.05% of range
DC: 0.02% of reading + 0.05% of range
50 kHz : 0.4% of reading + 0.1% of range
Accuracy for power (U7005) 50/60 Hz : 0.01% of reading + 0.02% of range
DC : 0.02% + 0.03% of reading of range
50 kHz: 0.15% of reading + 0.05% of range
Measurement range Voltage: 6 V, 15 V, 30 V, 60 V, 150 V, 300 V, 600 V, 1500 V
Current: (Probe1) 40 mA to 2 kA, (Probe2) 100 mA to 50 kA
(Probe1 : Hioki’s high-accuracy current sensor interface supports automatic identification and phase shift correction.
Probe 2: BNC I/F only for U7001)
Measurement parameters voltage (U), current (I), active power (P), apparent power (S), reactive power(Q), power factor (λ), phase angle (φ), voltage frequency(fU), current frequency(fI), efficiency (η), loss (Loss), voltage ripple factor (Urf), current ripple factor (Irf), current integration (Ih), power integration (WP), voltage peak (Upk), current peak (Ipk)– Harmonics measurement : (Wideband mode: Maximum analysis order 500th, IEC measurement mode)
– Waveform recording: recording capacity 5M words × ( [voltage/current] ) × – No. of channels + motor waveforms)
– Motor analysis (option): voltage, torque, RPM, frequency, slip, motor power
– FFT analysis (Power spectrum analysis)
– Flicker measurement
IEC measurement mode When the measurement line has a frequency of 50 Hz or 60 Hz, the instrument can perform harmonic measurements according to IEC61000-4-7 and voltage fluctuation/flicker measurements according to IEC61000-4-15
IEC-compliant harmonic measurement Compliant with IEC 61000-4-7:2002Analysis order: Harmonics: 0th to 200th orders, Inter-harmonic: 0.5th to 200.5th orders
IEC-compliant flicker measurement Compliant with IEC 61000-4-15:2010 Ed 2.0 Flickermeter Class F2Measurement items: Short-term flicker (Pst), Maximum short-term flicker value (PstMax), Long-term flicker value (Plt),
Maximum instantaneous flicker value (PinstMax), Minimum instantaneous flicker value (PinstMin), Relative steady-state voltage change (dc), Maximum relative voltage change (dmax), Period while the relative voltage change exceeds the threshold (Tmax)
Calculation function Efficiency and loss calculations, User-defined calculations, Delta conversion, Current sensor automatic phase shift calculation
Synchronization measurement Optical link: Up to two units, 16 channels maximum
BNC Synchronization: Up to four units, 32 channels maximum
External interface USB flash drive, LAN, GP-IB, RS-232C, external control, optical link, BNC sync., CAN or CAN FD
Power supply 100 V to 240 V AC, 50/60 Hz, 230 VA
Dimensions and mass Approx. 430 mm (16.93 in) W × 221 mm (8.70 in) H × 361mm (14.21 in) D, Approx. 14kg (493.84 oz)
Included accessories – Power cord ×1
– Instruction Manual ×1
– D-sub 25-pin connector ×1 (PW8001-02, -05, -12, -15 only)

Datasheet

PW8001