30 Jan

Hioki CT6875A AC/DC Current Sensor

WhatsApp for Price

 

Supports Current Measurement of Inverters with High Current and High Speed

Category: Brand:

Description

Hioki’s pass-through type AC/DC current sensors can be connected directly to Hioki Power Analyzers and Memory HiCorders. Also, it can be connected to Power Meters, Oscilloscopes, DMMs, etc. by using an optional sensor unit.
The CT6875A has a frequency bandwidth of DC to 2 MHz (Model CT6875A-1 is DC to 1.5 MHz) and a rated current of 500 A. It is used for R&D, quality evaluation, manufacturing, and maintenance in markets such as wireless charging systems, inverter motors for industrial equipment, power conditioners for PV, and quick charging facilities for EVs.

Use with an instrument with a high input impedance of 1 MΩ or higher.

Key Features

  • Combined accuracy with HIOKI power analyzer PW8001, PW6001 and PW3390 is specified. For details of combined accuracy, refer to the instruction manual.
  • Strengthened shield improves noise resistance to accurately measure current buried in noise
  • Flat frequency characteristics and CMRR performance to achieve high accuracy measurement
  • More enhanced environmental resistance performance than ever before with operating temperature range of -40 to 85°C
  • Good frequency characteristics over wide band of DC to 2 MHz (amplitude) and DC to 1 MHz (phase)
  • Ideal for advanced fields such as photovoltaics and fuel cells to evaluate the charge / discharge of batteries and secondary side of inverters
  • Connect with oscilloscopes or Hioki Memory HiCorders (using SENSOR UNIT) to monitor waveforms

Model No. (Order Code)

CT6875A Cable length: 3 m (9.84 ft.)
CT6875A-1 Cable length: 10 m (32.81 ft.)

Specification

Accuracy guaranteed: 1 year

Rated current 500 A AC/DC
Max. allowable input Within the derating range, up to ±1500 Apeak (design value) allowed at 40°C or less for 20 ms or less
Frequency bandwidth Amplitude: DC to 2 MHz (CT6875A), DC to 1.5 MHz (CT6875A-1)
Phase: DC to 1 MHz
Basic accuracy (DC, 45 Hz ≤ f ≤ 66 Hz) Amplitude: ±0.04 % rdg. ±0.008 % f.s., Phase: ±0.08°
Output voltage rate 4 mV / A rated (This device outputs AC+DC voltage via the Sensor Unit)
Max. rated voltage to earth 1000 V AC/DC (50/60 Hz, CAT III )
Core diameter φ 36 mm (1.42 in)
Operating temperature, humidity -40°C to +85°C (-40°F to 185°F), 80% RH or less (with no condensation)
Power supply Power suppled via the Power Analyzer PW8001, PW6001, PW3390, Sensor Unit CT9555, CT9556, CT9557, or 3CH CURRENT UNIT U8977
Max. rated power 7 VA max. (at 500 A/55 Hz)
Dimensions and mass 160 mm (6.30 in)W × 112 mm (4.41 in)H × 50 mm (1.97 in)D, CT6875A: 850 g (30 oz), cable length 3 m (9.84 ft), CT6875A-1: 1150 g (40.6 oz), cable length 10 m (32.81 ft)
Included accessories Instruction Manual ×1, Mark bands ×6, Operating Precautions ×1

 

Compatible models CT6875A
Power AnalyzerPW8001, PW6001, PW3390 Ok
Power Analyzer3390 Attention (Requires CT9901)
Power HiTester3193 series Attention (Requires CT9901)
Current Unit8971 Attention (Requires the 9318, CT9901)

Datasheet

Hioki CT6875A_CT6875A-01