21 Jul

Amprobe 33XR-A Digital Multimeter with Temperature

WhatsApp for Price

  • Min/max, relative, peak and data hold
  • Auto power off to save battery life
  • Separate door for easy battery and fuse access
  • Magne-Grip™ Holster with magnetic hanging strap
  • Display: 3-3/4 digit LCD, 3999 counts with 41-segment analog bar graph
  • Display update rate: 2/sec, nominal
  • Analog bar graph
  • Overrange indication
  • Operating temperature: 0 °C to 45 °C at < 70 % R.H.
  • Storage temperature: -20 °C to 60 °C,
  • Input warning tone when test leads are in wrong jack
SKU: 2727788 Category:

Description

The Amprobe 33XR-A is a manual ranging digital multimeter with temperature and capacitance for field service technicians.

Specification

FEATURE
33XR-A
DC Voltage
400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
AC Voltage
400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
DC Current
400.0 µA, 4.000 mA, 40.00 mA, 300.0 mA, 10 A
AC Current
400.0 µA, 4.000 mA, 40.00 mA, 300.0 mA, 10 A
Resistance
400.0 O, 40.00 kO, 4.000 MO
Continuity
Diode
VolTect™ Non-Contact Voltage Detection
Capacitance
4.000 µF, 40.00 µF, 400.0 µF, 4000 µF
Frequency
4.000 kHz, 40.00 kHz, 400.0 kHz, 1 MHz
Temperature
1832 °F (1000 °C)
Duty cycle
Logic test
Inductance
dBm
Specifications
DC Voltage ranges
400 mV, 4 V, 40 V, 400 V, 1000 V
DC Voltage accuracy
All ranges: ± (0.7 % rdg + 1 dgt)
DC Voltage resolution
100 µV
DC Voltage input impedance
10 MO
AC Voltage (45 Hz to 500 Hz) ranges
400 mV, 4 V, 40 V, 400 V, 750 V
AC Voltage (45 Hz to 500 Hz) accuracy
4 V Range, 200 Hz to 500 Hz: ± (2.0 % rdg + 4 dgts)

All other ranges: ± (1.5 % rdg + 4 dgts)
AC Voltage (45 Hz to 500 Hz) resolution
100 µV
AC Voltage (45 Hz to 500 Hz) input impedance
10 MO
DC Current ranges
400 µA, 4 mA, 40 mA, 300 mA, 10 A
DC Current accuracy
400 µA to 300 mA ranges: ± (1.0 % rdg + 1 dgt)

10 A range: ± (2.0 % rdg + 3 dgts)
DC Current resolution
0.1 µA
DC Current voltage burden
400 µA range: 1 mV/µA, 4 mA range: 100 mV/1 mA, 40 mA range: 12 mV/1 mA

300 mA range: 4 mV/1 mA, 10 A range: 100 mV/1 A
AC Current (45 Hz to 500 Hz) ranges
400 µA, 4 mA, 40 mA, 300 mA, 10 A
AC Current (45 Hz to 500 Hz) accuracy
400 µA to 300 mA ranges: ± (1.5 % rdg + 4 dgts)

10 A range: ± (2.5 % rdg + 4 dgts)
AC Current resolution
0.1 µA
AC Current voltage burden
See DC Current
Resistance ranges
400 O 40 kO 4 MO
Resistance accuracy
400 Oand 40 kO ranges: ± (1.0 % rdg + 4 dgts)

4 MO range: ± (1.2 % rdg + 4 dgts)
Resistance resolution
100 mO

Datasheet

Amprobe-33XR-A-Digital-Multimeter-with-Temperature