- Non-contact voltage detector
- Separate door for easy battery and fuse access
- Manual ranging; display: 3-1/2 digit LCD, 1999 counts
- Display update rate: 2.5/sec, nominal
- Power battery: 9 V NEDA 1604, JIS 006P, IEC 6F22
- Operating temperature: 0 °C to 45 °C at < 70 % R.H.
- Storage temperature: -20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter
- Low battery indication
- Overrange indication
- Min/max and data Hold
Description
For non-contact voltage testing, Amprobe 30XR-A Digital Multimeter offers Voltect™ non-contact voltage technology built into the 30XR-A along with a full complement of measurement functions.
Specification
FEATURE |
30XR-A |
DC Voltage |
200.0 mV 2.000 V, 20.00 V, 200.0 V, 500 V |
AC Voltage |
200.0 mV 2.000 V, 20.00 V, 200.0 V, 500 V |
DC Current |
200.0 µA 2.000 mA, 20.00 mA, 200.0 mA, 10 A |
AC Current |
200.0 µA 2.000 mA, 20.00 mA, 200.0 mA, 10 A |
Resistance |
200.0 O, 2.000 kO, 20.00 kO, 200.0 kO, 2.000 MO, 20.00 MO |
Continuity |
• |
Diode |
• |
VolTect™ Non-Contact Voltage Detection |
• |
Capacitance |
– |
Frequency |
– |
Temperature |
– |
Duty cycle |
– |
Logic test |
– |
Inductance |
– |
dBm |
– |
Specifications |
|
DC Voltage ranges |
200 mV, 2 V, 20 V, 200 V, 600 V |
DC Voltage accuracy |
All ranges: ± (1 % rdg + 1 dgt) |
DC Voltage resolution |
100 µV |
DC Voltage input impedance |
10 MO |
AC Voltage (45 Hz to 500 Hz) ranges |
200 mV, 2 V, 20 V, 200 V, 600 V |
AC Voltage (45 Hz to 500 Hz) accuracy |
All ranges: ± (1.5 % rdg + 4 dgts) |
AC Voltage (45 Hz to 500 Hz) resolution |
100 µV |
AC Voltage (45 Hz to 500 Hz) input impedance |
10 MO |
DC Current ranges |
200 µA, 2 mA, 20 mA, 200 mA, 10 A |
DC Current accuracy |
200 µA to 200 mA ranges: ± (1.5 % rdg + 1 dgt) 10 A range: ± (2.0 % rdg + 3 dgts) |
DC Current resolution |
0.1 µA |
DC Current voltage burden (max) |
200 µA range: 1 mV/µA 2 mA range: 100 mV/1mA 20 mA range: 13 mV/1 mA 200 mA range: 4.6 mV/1 mA 10 A range: 40 mV/1 A |
AC Current (45 Hz to 500 Hz) ranges |
200 µA, 2 mA, 20 mA, 200 mA, 10 A |
AC Current (45 Hz to 500 Hz) accuracy |
200 µA to 200 mA ranges: ± (2.0 % rdg + 4 dgts) 10 A range: ± (2.5 % rdg + 4 dgts) |
AC Current resolution |
0.1 µA |
AC Current voltage burden |
See DC Current |
Non-contact voltage detector (NCV) AC volts |
70 to 600 V AC |
Non-contact voltage detector (NCV) |
Red LED and Audible Indicator |